Standard Practice for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Theis Nonequilibrium Method
Importancia y uso:
5.1 Assumptions:
5.1.1 Well discharges at a constant rate, Q.
5.1.2 Well is of infinitesimal diameter and fully penetrates the aquifer.
5.1.3 The nonleaky aquifer is homogeneous, isotropic, and aerially extensive. A nonleaky aquifer receives insignificant contribution of water from confining beds.
5.1.4 Discharge from the well is derived exclusively from storage in the aquifer.
5.1.5 The geometry of the assumed aquifer and well conditions are shown in Fig. 1.
5.2.3 Application of Theis Method to Unconfined Aquifers:
5.2.3.1 Although the assumptions are applicable to artesian or confined conditions, the Theis solution may be applied to unconfined aquifers if drawdown is small compared with the saturated thickness of the aquifer or if the drawdown is corrected for reduction in thickness of the aquifer, and the effects of delayed gravity yield are small.
5.2.3.2 Reduction in Aquifer Thickness—In an unconfined aquifer dewatering occurs when the water levels decline in the vicinity of a pumping well. Corrections in drawdown need to be made when the drawdown is a significant fraction of the aquifer thickness as shown by Jacob (5). The drawdown, s, needs to be replaced by s′, the drawdown that would occur in an equivalent confined aquifer, where:
5.2.3.3 Gravity Yield Effects—In unconfined aquifers, delayed gravity yield effects may invalidate measurements of drawdown during the early part of the test for application to the Theis method. Effects of delayed gravity yield are negligible in partially penetrating observation wells at and beyond a distance, r, from the control well, where:
After the time, t, as given in Eq 9 from Neuman (6).
Sy = the specific yield. For fully penetrating observation wells, the effects of delayed yield are negligible at the distance, r, in Eq 8 after one tenth of the time given in the Eq 9.
Note 1: The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself ensure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.
Subcomité:
D18.21
Referida por:
D4050-20, D4043-17, D4105_D4105M-20, D0653-24A, D5472_D5472M-20, D5270_D5270M-20, D5920_D5920M-20, D6029_D6029M-20, D6028_D6028M-20
Volúmen:
04.08
Número ICS:
93.160 (Hydraulic construction)
Palabras clave:
aquifer tests; aquifers; control wells; groundwater; hydraulic conductivity; observation wells; storage coefficient; transmissivity;
$ 1,097
Norma
D4106
Versión
20
Estatus
Active
Clasificación
Practice
Fecha aprobación
2020-06-01
