Standard Practice for Pre-Installation Acceptance Testing of Vibrating Wire Piezometers
Importancia y uso:
4.1 Vibrating wire piezometers are typically not recoverable after installation. Replacement, which involves drilling a new borehole, is expensive and sometimes impossible. Thus it is important to be certain that the sensor is operational before it is installed.
4.2 Lacking sophisticated testing facilities, field testers must use equipment that is at hand. But in so doing, field testers should not expect to achieve the same accuracy and precision that manufacturers state on the sensor calibration record. Instead, field testers should look for obvious non-conformances, as explained in the procedures.
4.3 This standard practice is not meant to restrict the use of other appropriate acceptance tests and procedures.
Note 1: The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.
Subcomité:
D18.23
Volúmen:
04.09
Número ICS:
93.020 (Earth works. Excavations. Foundation construction. Underground works)
Palabras clave:
acceptance test; vibrating wire piezometers;
$ 954
Norma
D7764
Versión
20
Estatus
Active
Clasificación
Practice
Fecha aprobación
2020-08-01