Standard Practice for (Analytical Procedure) Determining the Efficiency of a Production Well in a Confined Aquifer from a Constant Rate Pumping Test


Importancia y uso:

5.1 This practice allows the user to compute the true hydraulic efficiency of a pumped well in a confined aquifer from a constant rate pumping field test. The procedures described constitute the only valid method of determining well efficiency. Some practitioners have confused well efficiency with percentage of head loss associated with laminar flow, a parameter commonly determined from a step-drawdown test. Well efficiency, however, cannot be determined from a step-drawdown test but only can be determined from a constant rate test.

5.2 Assumptions: 

5.2.1 Control well discharges at a constant rate, Q.

5.2.2 Control well is of infinitesimal diameter.

5.2.3 Data are obtained from the control well and, if available, a number of observation wells.

5.2.4 The aquifer is confined, homogeneous, and extensive. The aquifer may be anisotropic, and if so, the directions of maximum and minimum hydraulic conductivity are horizontal and vertical, respectively.

5.2.5 Discharge from the well is derived exclusively from storage in the aquifer.

5.3 Calculation Requirements—For the special case of partially penetrating wells, application of this practice may be computationally intensive. The function fs shown in Eq 6 should be evaluated using arbitrary input parameters. It is not practical to use existing, somewhat limited, tables of values for fs and, because this equation is rather formidable, it may not be tractable by hand. Because of this, it is assumed the practitioner using this practice will have available a computerized procedure for evaluating the function fs. This can be accomplished using commercially available mathematical software including some spreadsheet applications. If calculating fs is not practical, it is recommended to substitute the Kozeny equation for the Hantush equation as previously described.

Note 1: The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this standard are cautioned that compliance with Practice D3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D3740 provides a means of evaluating some of those factors.

Note 2: Commercially available software is available for the calculating, graphing, plotting, and analyses of this practice. The user is responsible for verifying the correctness of the formulas, graphs, plots and analyses of the software.

Subcomité:

D18.21

Volúmen:

04.09

Número ICS:

93.160 (Hydraulic construction)

Palabras clave:

anisotropy; aquifers; aquifer tests; control wells; groundwater; hydraulic conductivity; observation wells; storage coefficient; transmissivity; well efficiency;

$ 1,086

Agregar al carrito

Norma
D6034

Versión
20

Estatus
Active

Clasificación
Practice

Fecha aprobación
2020-06-01