Standard Practice for Evaluation of Fire-Retardant Treated Laminated Veneer Lumber
Importancia y uso:
5.1 Design values obtained from 4.2 are permitted for use in design where the end-use temperature does not exceed 38 °C (100 °F).
5.1.1 The mean test values for the properties evaluated in 4.2 (ftr,0) and 4.3 (ftr,108) shall be used to determine design value adjustment factors for FRT LVL that will be exposed to end-use temperatures in excess of 38 °C (100 °F) but not exceeding 66 °C (150 °F). Temperature adjustment factors in accordance with the National Design Specification for Wood Construction (NDS) shall also be applied in these applications.
Subcomité:
D07.07
Volúmen:
04.10
Número ICS:
71.100.50 (Wood-protecting chemicals)
Palabras clave:
design value adjustment factor; fire retardant; fire-retardant treated; FRT; laminated veneer lumber; LVL; mechanical properties; physical properties;