Standard Test Method for Insulating Glass Unit Performance
Importancia y uso:
4.1 This test method is intended to provide a means for testing the performance of the sealing system and construction of insulating glass units.
4.1.1 Insulating glass units tested in accordance with this method may be suitable for structurally glazed applications. However, factors such as sealant longevity when exposed to long term ultraviolet light and the structural properties of the sealant must be reviewed for these applications.
4.1.2 Insulating glass units tested in accordance with this method are not intended for continuous exposure to high relative humidity conditions or long-term immersion in water.
Subcomité:
E06.22
Referida por:
E2189-19, E2190-19, C1249-18R23, E2269-21
Volúmen:
04.12
Número ICS:
81.040.01 (Glass in general)
Palabras clave:
IGU performance; IGU seal durability; insulating glass units; insulating glass units (IGU);
$ 1,087
Norma
E2188
Versión
19
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2019-04-01