Importancia y uso:

4.1 Although it is possible to observe and measure each of the several characteristics of a detector under different and unique conditions, it is the intent of this recommended practice that a complete set of detector specifications should be obtained at the same operating conditions, including geometry, flow rates, and temperatures. It should be noted that to specify a detector’s capability completely, its performance should be measured at several sets of conditions within the useful range of the detector. The terms and tests described in this recommended practice are sufficiently general so that they may be used at whatever conditions may be chosen for other reasons.

4.2 The FID is generally only used with non-ionizable supercritical fluids as the mobile phase. Therefore, this standard does not include the use of modifiers in the supercritical fluid.

4.3 Linearity and speed of response of the recording system or other data acquisition device used should be such that it does not distort or otherwise interfere with the performance of the detector. Effective recorder response, Bonsall (5) and McWilliam (6), in particular, should be sufficiently fast so that it can be neglected in sensitivity of measurements. If additional amplifiers are used between the detector and the final readout device, their characteristics should also first be established.

Subcomité:

E13.19

Referida por:

D2163-23E01, D4291-21R25, D4291-21R25, D5599-22, D7165-22, D7823-20, D5599-22, D3465-21, D2887-24, D7169-23, D6584-21, D7213-23, E0260-96R26, D5501-20R24E01, E1747-95R26, D6584-21, D7796-21, D7083-16R22, D2268-21R25, D5134-21R25, D5134-21R25, D5501-20R24E01, D7920-21, D7096-25, D6352-24, D7753-24, D7398-23, D7716-11AR24, D7993-15R19, D5441-21R25, D4291-21R25, D7798-24, D7593-22, D7875-24, D6296-22, D4526-20, D8133-23, D6730-22, D4275-17, D7169-23, D7096-25, D5501-20R24E01, D7059-21, D6417-25, D2163-23E01, D7500-24, D3525-20, D6733-24, D8302-25, D6584-21, D7922-23, D2887-24, D7974-21, D2163-23E01, D5599-22, D7164-21, D6729-25, D3524-14R20, D6417-25, D2163-23E01, D2887-24, D7169-23, D7756-19, D6729-25, D5504-20, D7756-19, D7756-19, D7756-19, D5504-20, D8396-22, D6730-22, D3524-14R20, D3525-20, D5504-20, D8442-22, D5504-20

Volúmen:

03.06

Número ICS:

17.180.30 (Optical measuring instruments), 71.040.50 (Physicochemical methods of analysis)

Palabras clave:

flame ionization detector (FID); flame photometric detectors (FPD); gas chromatography (GC); packed columns; supercritical fluid chromatography (SFC);

$ 1,279

Agregar al carrito

Norma
E594

Versión
96(2026)

Estatus
Active

Clasificación
Practice

Fecha aprobación
2026-01-01