Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors


Importancia y uso:

5.1 The impact sound rating for a floor assembly is determined both by the basic floor assembly and the floor covering on the upper surface. The same floor covering in combination with different basic floor assemblies will not always give the same impact insulation class (IIC) and high-frequency impact insulation class (HIIC) ratings. This test method is designed to provide data that characterize the floor covering alone when installed over concrete slab floors.

5.2 The ΔIIC and ΔHIIC ratings calculated in 13.4 are used to compare the effectiveness of different floor coverings on concrete floors.

5.3 The impact insulation class (IIC) and high-frequency impact insulation class (HIIC) calculated for the reference concrete floor with a covering provide an indication of the impact sound insulation that the covering will provide with typical, monolithic concrete floors.

5.4 When the normalized impact sound pressure levels below a bare concrete slab are known, the difference spectrum calculated in 13.1 may be used to estimate the impact sound pressure levels and hence the IIC and HIIC that would result if the covering were installed on the slab.

5.5 Warning: Difference spectra measured using this method shall not be used to estimate impact sound pressure levels for floors comprising only one or two lightweight floor layers such as oriented strand board or plywood. Such estimated impact sound pressure levels would be very inaccurate.

Note 1: The difference spectrum calculated in 13.1 gives unreliable estimates of the reduction in impact sound pressure levels due to the floor covering when it is placed on a joist floor incorporating a concrete topping (about 50 mm thick) poured directly on the plywood subfloor or steel deck. The estimated impact sound pressure levels are too low.4

5.6 This test method closely follows that described in ISO 10140-1 (Annex H) except that the single number ratings used are the impact insulation class (IIC) described in Classification E989 and the high-frequency impact insulation class (HIIC) described in Classification E3222. The description of the standard concrete floor between the two methods also differs.

Note 2: The requirement in Classification E989 that no deviation above the reference contour may exceed 8 dB means that there is no simple relationship between ISO 10140-1 (Annex H) test ratings and those generated by this method.

Subcomité:

E33.10

Referida por:

E0989-21, E3222-20A, C0634-22, E2813-24

Volúmen:

04.06

Número ICS:

91.120.20 (Acoustics in buildings. Sound insulation)

Palabras clave:

high-frequency impact insulation class; impact insulation class; impact sound insulation; impact sound pressure level; tapping machine;

$ 1,243

Agregar al carrito

Norma
E2179

Versión
25

Estatus
Active

Clasificación
Test Method

Fecha aprobación
2025-10-15