Standard Guide for Assessing Depressurization-Induced Backdrafting and Spillage from Vented Combustion Appliances


Importancia y uso:

5.1 Although a number of different methods have been used to assess backdrafting and spillage (see NFPA 54/ANSI Z223.1, CAN/CGSB-51.71, and 1-4)6 a single well-accepted method is not yet available. At this point, different methods can yield different results. In addition, advantages and drawbacks of different methods have not been evaluated or described.

5.2 To provide a consistent basis for selection of methods, this guide summarizes different methods available to assess backdrafting and spillage. Advantages and limitations of each method are addressed.

5.3 One or more of the methods described in this guide should be performed when backdrafting or spillage from vented combustion appliances is suspected to be the cause of a potential problem such as elevated carbon monoxide (CO) levels or excessive moisture.

5.4 The following are examples of specific conditions under which such methods could be performed:

5.4.1 When debris or soot is evident at the draft hood, indicating that backdrafting may have occurred in the past,

5.4.2 When a new or replacement combustion appliance is added to a residence,

5.4.3 When a new or replacement exhaust device or system, such as a downdraft range exhaust fan, a fireplace, or a fan-powered radon mitigation system, is added,

5.4.4 When a residence is being remodeled or otherwise altered to increase energy efficiency, as with various types of weatherization programs, and

5.4.5 When a CO alarm device has alarmed and a combustion appliance is one of the suspected causes of the alarm.

5.5 Depending on the nature of the test(s) conducted and the test results, certain preventive or remedial actions may need to be taken. The following are examples:

5.5.1 If any of the short-term tests indicates a potential for backdrafting, and particularly if more than one test indicates such potential, then the appliance and venting system should be further tested by a qualified technician, or remedial actions could be taken in accordance with 5.5.3.

5.5.2 If continuous monitoring indicates that backdrafting is occurring, and particularly if it indicates that spillage is occurring that impacts indoor air quality (for example, elevated CO concentrations or excessive moisture in the house), then remedial action is indicated.

5.5.3 Possible remedial actions include the following:

5.5.3.1 At a minimum, a CO alarm device could be installed in the house.

5.5.3.2 Limiting the use of devices or systems that increase house depressurization, such as fireplaces and high-volume exhaust fans. Proper sealing of any air leakage sites, especially at the top floor ceiling level, can also reduce house depressurization at the lower levels of the house.

5.5.3.3 Partially opening a window in the furnace or appliance room, if available. Keeping the door nearest the appliance room open at all times or putting louvers in the door.

5.5.3.4 Providing increased makeup air for the appliance (for example, by providing a small duct or opening to the outdoors near the appliance).

5.5.4 If remedial actions are not successful, then consideration can be given to correcting or replacing the venting system or, if necessary, replacing the spilling appliance with one that can better tolerate house depressurization.

5.6 The understanding related to backdrafting and spillage phenomena is evolving. Comprehensive research using a single, reliable method is needed to better understand the frequency, duration, and severity of depressurization-induced spillage in a broad cross section of homes (5). In the absence of a single well-accepted method for assessing the potential for or occurrence of backdrafting or spillage, alternative methods are presented in this guide. The guide is intended to foster consistent application of these methods in future field work or research. The resultant data will enable informed decisions on relative strengths and weaknesses of the different methods and provides a basis for any refinements that may be appropriate. Continued efforts along these lines will enable the development of specifications for a single method that is acceptable to all concerned.

Subcomité:

E06.41

Volúmen:

04.11

Número ICS:

91.140.65 (Water heating equipment)

Palabras clave:

backdrafting; carbon dioxide; carbon monoxide; combustion appliances; downdrafting; draft diverter; draft hood; flue gas; house depressurization; house tightness; induced fan; nitrogen oxides; residences; spillage; water vapor;