Standard Test Method to Measuring the Post Dispensing Volumetric Expansion of Aerosol Foam Sealants
Importancia y uso:
5.1 Post dispensing volumetric expansion factor F indicates the ratio of the fully cured foam sealant volume and the initially dispensed foam sealant volume. For example, if the expansion factor F were 2, the fully cured foam would double its initial volume; therefore, one should fill 50 % of the cavity uniformly to anticipate the full coverage upon curing.
5.2 Post dispensing volumetric expansion factor F does not predict the performance capability of the foam sealants of the suitability for the intended applications.
5.3 This test method is intended to lend guidance in product selection as related to the post dispensing expansion characteristics of the aerosol foam sealants.
5.4 This test method recognizes that the results are reflective of controlled laboratory conditions. Post dispensing expansion in field applications may vary according to temperature, humidity, and surfaces that the aerosol foam sealants are in contact with.
Subcomité:
C24.61
Referida por:
C1852-20, C1620-16R23
Volúmen:
04.07
Número ICS:
91.100.50 (Binders. Sealing materials)
Palabras clave:
aerosol; aerosol foam; air barrier from sealant; air exfiltration; air infiltration; foam sealant; latex foam sealant; polyurethane foam sealant;
$ 1,049
Norma
C1643
Versión
14(2024)
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2024-11-01
