Standard Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution
Importancia y uso:
3.1 This test method provides a means of assessing the sulfate resistance of mortars made using portland cement, blends of portland cement with pozzolans or slags, and blended hydraulic cements. Test Method C452 is suitable for evaluating portland cements but not blended cements or blends of portland cement with pozzolans or slags.
3.2 The standard exposure solution used in this test method, unless otherwise directed, contains 352 moles of Na2SO4 per m3(50 g/L). Other sulfate concentrations or other sulfates such as MgSO4 may be used to simulate the environmental exposure of interest. Further discussion of these and other technical issues is given in the Appendix.
Subcomité:
C01.29
Referida por:
C1600_C1600M-23, C1240-20, C1240-20, C1894-22, C1709-22, C0595_C0595M-24, C0183_C0183M-23, C0183_C0183M-23, C0595_C0595M-24, C1157_C1157M-23, C0989_C0989M-24, C0989_C0989M-24, C0989_C0989M-24, C0183_C0183M-23, C1157_C1157M-23, C0595_C0595M-24, C1157_C1157M-23, C1240-20, C0311_C0311M-24, C0311_C0311M-24, C0311_C0311M-24, C1904-22
Volúmen:
04.01
Número ICS:
91.100.10 (Cement. Gypsum. Lime. Mortar)
Palabras clave:
acceptability; expansion; fly ash; mortars; pozzolans; precision; search report; slag; sulfate attack; sulfate-resisting cements; tests ;
$ 1,187
Norma
C1012/C1012M
Versión
24a
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2024-10-15