Standard Test Method for Automatic Particle Counting and Particle Shape Classification of Oils Using a Direct Imaging Integrated Tester


Importancia y uso:

5.1 This test method is intended for use in analytical laboratories including on-site in-service oil analysis laboratories. Periodic sampling and analysis of lubricants have long been used as a means to determine overall machinery health. Atomic emission spectroscopy (AES) is often employed for wear metal analysis (Test Methods D5185 and D6595). A number of physical property tests complement wear metal analysis and are used to provide information on lubricant condition (Test Methods D445, D2896, D6304, and D7279). Molecular spectroscopy (Practice E2412) provides direct information on molecular species of interest including additives, lubricant degradation products and contaminating fluids such as water, fuel and glycol. Direct imaging integrated testers provide complementary information on particle count, particle size, particle type, and soot content.

5.2 Particles in lubricating and hydraulic oils are detrimental because they increase wear, clog filters and accelerate oil degradation.

5.3 Particle count may aid in assessing the capability of a filtration system to clean the fluid, determine if off-line recirculating filtration is needed to clean the fluid, or aid in the decision whether or not to change the fluid.

5.4 An increase in the concentration and size of wear particles is indicative of incipient failure or component change out. Predictive maintenance by oil analysis monitors the concentration and size of wear particles on a periodic basis to predict failure.

5.5 High soot levels in diesel engine lubricating oil may indicate abnormal engine operation.

Subcomité:

D02.96.07

Referida por:

E3338-22, D8128-22, D7684-11R20, D7720-21, D8323-24

Volúmen:

05.04

Número ICS:

75.100 (Lubricants, industrial oils and related products), 75.120 (Hydraulic fluids)

Palabras clave:

condition monitoring; contaminant particles; contamination; direct imaging integrated tester; ISO codes; particle count; soot; wear; wear particles;

$ 1,196

Agregar al carrito

Norma
D7596

Versión
24

Estatus
Active

Clasificación
Test Method

Fecha aprobación
2024-10-01