Standard Guide for Performance Attributes of Waterproofing Membranes Applied to Below-Grade Walls / Vertical Surfaces (Enclosing Interior Spaces)
Importancia y uso:
4.1 A waterproofing membrane should maintain its watertight integrity for the life of the building in a continuously or intermittently moist environment and may be subject to continuous or intermittent hydrostatic pressure. It should resist chemicals that can harm the membrane and root growth. This guide lists minimum performance attributes required of waterproofing membranes applied to below-grade walls. Products not previously used as waterproofing membrane materials require additional tests beyond the scope of this guide. This guide is not intended for use on in-service waterproofing materials. Waterproofing membranes and other components should conform to ASTM product standards, if available.
4.2 Limitations—Prior to use and in service, waterproofing may be exposed to a variety of conditions so no one test will provide evaluations related to performance for all exposures. Neither will all tests be necessary in all evaluations for specific exposures.
Subcomité:
D08.22
Volúmen:
04.04
Número ICS:
91.120.30 (Waterproofing)
Palabras clave:
bacteria resistances; chemical resistances; cyclical fatigues; hydrostatic pressures; liquid-applied; moisture contents; performance levels; single and multi-ply; waterproofing membranes;
$ 954
Norma
D7832/D7832M
Versión
24
Estatus
Active
Clasificación
Guide
Fecha aprobación
2024-06-15