Standard Test Method for Tension Testing of Calcium Phosphate and Metallic Coatings
Importancia y uso:
5.1 The tensile test method is recommended for tension testing of calcium phosphate/substrate or porous metal coating/substrate combinations and can provide information on the adhesive or cohesive strength of coatings under (uniaxial) tensile stress.
5.2 The test method may be useful for comparative evaluation of adhesive or cohesive strengths of a variety of types of coatings. Coatings may be applied using a variety of methods, including but not limited to, plasma-spraying and sintering. Information developed using this test method may be useful for certain quality control and design purposes.
5.3 The test should not be considered to provide an intrinsic value for utilization directly in making calculations such as determining the ability of a coating to withstand specified environmental stresses.
5.4 Processing variables such as substrate preparation prior to coating, surface texture, coating technique variables, or post-coating heat treatment variables may introduce a significant effect on the results of the tension test. The specimen being evaluated must be representative of the actual end-use coating.
Subcomité:
F04.15
Referida por:
F2887-23, F1609-23, F1378-18E01, F0561-19
Volúmen:
13.01
Número ICS:
25.220.40 (Metallic coatings)
Palabras clave:
adherence; ceramic materials; hydroxylapatite; interface; porous coating; tension testing; tribasic calcium phosphate;
$ 1,122
Norma
F1147
Versión
24
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2024-05-01