Standard Test Method for Total Carbon, Inorganic Carbon, and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Conductivity Detection


Importancia y uso:

5.1 This test method is used for determination of the carbon content of water from a variety of natural, domestic, and industrial sources. In its most common form, this test method is used to measure organic carbon as a means of monitoring organic pollutants in high purity and drinking water. These measurements are also used in monitoring waste treatment processes.

5.2 The relationship of TOC to other water quality parameters such as chemical oxygen demand (COD) and total oxygen demand (TOD) is described in the literature (6).

Subcomité:

D19.06

Referida por:

D5173-15R23, D6908-06R17, E2656-16, E2656-16, D5173-15R23

Volúmen:

11.02

Número ICS:

13.060.50 (Examination of water for chemical substances)

Palabras clave:

carbon; carbon-dioxide; inorganic-carbon; low-temperature-oxidation; membrane-conductivity-detection; organic carbon; total carbon;

$ 1,086

Agregar al carrito

Norma
D5904

Versión
02(2024)

Estatus
Active

Clasificación
Test Method

Fecha aprobación
2024-04-01