Standard Test Method for Modified Fouling Index (MFI-0.45) of Water
Importancia y uso:
5.1 This test method is an alternative for the silt density index (SDI) method (Test Method D4189) with the aim to overcome inaccuracies related to a nonlinear relation with the fouling potential due to particulate matter concentration, absence of temperature correction, support pad, and time.
5.2 The MFI-0.45 can serve as a useful indication of the quantity of particulate matter.
5.3 The MFI-0.45 can be used to determine effectiveness of various processes such as filtration or clarification used to remove particulate matter.
5.4 The MFI-0.45 has empirically been correlated with fouling tendency of some water treatment equipment such as reverse osmosis (RO) devices.
Subcomité:
D19.08
Volúmen:
11.02
Palabras clave:
fouling; membranes; modified fouling index; water;
$ 1,092
Norma
D8002
Versión
24
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2024-04-01