Standard Practice for Installation and Use of Reflective Insulation in Building Constructions
Importancia y uso:
4.1 This practice recognizes that effectiveness, safety, and durability of reflective insulation depends not only on the quality of the insulating materials, but also on proper installation.
4.2 There is potential for reduced thermal effectiveness, fire risks and structural deterioration when the insulation is improperly installed. Specific potential hazards from improper installation include fires caused by (1) heat build-up in recessed lighting fixtures, and (2) deterioration in wood structures and paint failure due to moisture accumulation.
4.3 This practice provides procedures for the installation of reflective insulation in a safe and effective manner. Actual conditions in existing buildings vary greatly and in some cases additional care must be taken to ensure safe and effective installation.
4.4 This practice presents requirements that are general in nature and practical. They are not intended as specific installation instructions. The user shall consult the manufacturer for specific applications/installations.
Subcomité:
C16.21
Referida por:
C1224-22
Volúmen:
04.06
Número ICS:
91.120.10 (Thermal insulation of buildings)
Palabras clave:
building constructions; enclosed air space; insulation system; low emittance; metallic foil; reflective insulation; thermal insulating materials ;
$ 952
Norma
C727
Versión
19(2024)
Estatus
Active
Clasificación
Practice
Fecha aprobación
2024-03-01