Standard Practice for Collection of Settled Dust Samples Using Wipe Sampling Methods for Subsequent Lead Determination
Importancia y uso:
5.1 This practice is intended for the collection of settled dust samples in and around buildings and related structures for the subsequent determination of lead content in a manner consistent with that described in the HUD Guidelines and 40 CFR 745.63. The practice is meant for use in the collection of settled dust samples that are of interest in clearance, hazard assessment, risk assessment, and other purposes.
5.2 Use of different pressures applied to the sampled surface along with the use of different wiping patterns contribute to collection variability. Thus, the sampling result can vary between operators performing collection from identical surfaces as a result of collection variables. Collection for any group of sampling locations at a given sampling site is best when limited to a single operator.
5.3 This practice is recommended for the collection of settled dust samples from hard, relatively smooth, nonporous surfaces. This practice is less effective for collecting settled dust samples from surfaces with substantial texture such as rough concrete, brickwork, textured ceilings, and soft fibrous surfaces such as upholstery and carpeting.
Subcomité:
D22.12
Referida por:
E3074_E3074M-24, E1792-24, E1644-21, E1775-24, D7659-21, D8344-24, E2115-22, E2271_E2271M-22
Volúmen:
11.07
Número ICS:
13.080.05 (Examination of soil in general)
Palabras clave:
lead; sample collection; settled dust; wipe;
$ 1,087
Norma
E1728/E1728M
Versión
24
Estatus
Active
Clasificación
Practice
Fecha aprobación
2024-03-01