Standard Guide for Development of Coverage Charts for Loose-Fill Thermal Building Insulations


Importancia y uso:

5.1 Coverage charts list the required installed and product in-service parameters of minimum thickness, maximum net coverage per package, and minimum mass per unit area to achieve each listed thermal performance (R-value) level. Chart information corresponds to numerous standard R-value levels representing common building codes, industry standards, or legislated requirements (see example in the Appendix X1) and therefore additional chart columns may be required, that is, number of packages per 1 000 ft2  (100m2), and initial installed thickness.

5.2 This guide applies to coverage charts for installations in open, horizontal attic floor spaces. Chart maximum net coverages are based upon net floor area; framing area deducted. Sloped ceilings, HVAC equipment and ductwork, and other factors can significantly influence product coverage and are to be considered by the manufacturer.

Subcomité:

C16.23

Referida por:

C0764-19, C0739-24

Volúmen:

04.06

Número ICS:

91.100.60 (Thermal and sound insulating materials)

Palabras clave:

coverage chart; loose-fill insulation; thermal insulation;