Standard Test Method for Determination of Trace Elements in Soda-Lime Glass Samples Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Forensic Comparisons
Importancia y uso:
5.1 This test method is useful for the determination of elemental concentrations in the range of approximately 0.1 µgg-1 to 10 percent (%) (See Table X1.1) in soda-lime glass samples (7 and 8). A standard test method can aid in the interchange of data between laboratories and in the creation and use of glass databases.
5.2 The determination of elemental concentrations in glass provides high discriminating value in the forensic comparison of glass fragments.
5.3 This test method produces minimal destruction of the sample. Microscopic craters of 50 µm to 100 µm in diameter by 80 µm to 150 µm deep are left in the glass fragment after analysis. The mass removed per replicate is approximately 0.4 µg to 3 µg (6).
5.4 Appropriate sampling techniques shall be used to account for natural heterogeneity of the materials at a microscopic scale.
5.5 The precision, bias, and limits of detection of the method (for each element measured) shall be established during validation of the method. The measurement uncertainty of any concentration value used for a comparison shall be recorded with the concentration.
5.6 Acid digestion of glass followed by either Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) or Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) can also be used for trace elemental analysis of glass, and offer similar detection levels and the ability for quantitative analysis. However, these methods are destructive, and require larger sample sizes and more sample preparation (Test Method E2330).
5.7 Micro X-Ray Fluorescence (µ-XRF) uses comparable sample sizes to those used for LA-ICP-MS with the advantage of being non-destructive of the sample. Some of the drawbacks of µ-XRF include lower sensitivity and precision, and longer analysis time (Test Method E2926).
5.8 Scanning Electron Microscopy with Energy Dispersive Spectrometry (SEM-EDS) is also available for elemental analysis, but it is of limited use for forensic glass source discrimination due to poor detection limits for higher atomic number elements present in glass at trace concentration levels. However, distinguishing between sources having similar RIs and densities is sometimes possible.
Subcomité:
E30.15
Referida por:
E1732-24E01
Volúmen:
14.02
Número ICS:
07.140 (Forensic science), 71.040.40 (Chemical analysis), 81.040.10 (Raw materials and raw glass)
Palabras clave:
forensic science; glass comparisons; glass measurement; trace elemental analysis; laser ablation; inductively coupled plasma mass spectrometry; LA-ICP-MS;
$ 1,190
Norma
E2927
Versión
23
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2023-11-15
