Standard Test Method for Determination of Elements in Insulating Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)


Importancia y uso:

5.1 This test method covers the rapid determination of 12 elements in insulating oils, and it provides rapid screening of used oils for indications of wear. Test times approximate several minutes per test specimen, and detectability is in the 10 μg/kg through 100 μg/kg range.

5.2 This test method can be used to monitor equipment condition and help to define when corrective action is needed. It can also be used to detect contamination such as from silicone fluids (via Silicon) or from dirt (via Silicon and Aluminum).

5.3 This test method can be used to indicate the efficiency of reclaiming used insulating oil.

Subcomité:

D27.03

Referida por:

D0117-22

Volúmen:

10.03

Número ICS:

29.040.10 (Insulating oils)

Palabras clave:

aluminum; cadmium; copper; emission-spectrometry; ICP; inductively coupled plasma atomic emission spectrometry; insulating liquid; iron; lead; silicon; silver; sodium; tin; transformer oil; tungsten; wear metals; zinc;

$ 1,092

Agregar al carrito

Norma
D7151

Versión
15(2023)

Estatus
Active

Clasificación
Test Method

Fecha aprobación
2023-12-01