Standard Guide for Reduction of Efflorescence Potential in New Masonry Walls
Importancia y uso:
4.1 This guide provides information that, if implemented, will reduce efflorescence potential in new masonry walls. However, implementation of this guide will not always completely prevent efflorescence.
4.2 This guide may be augmented by related information contained in the appendixes of Specification C270, the additional material listed at the end of this specification, and other publications.
Subcomité:
C15.05
Referida por:
C1713-24, E2266-22
Volúmen:
04.05
Número ICS:
91.080.30 (Masonry)
Palabras clave:
efflorescence; end dam; flashing; masonry units; mortar; preconstruction testing; water penetration; weep holes;