Standard Test Method for Passing Ability of Self-Consolidating Concrete by J-Ring


Importancia y uso:

5.1 This test method provides a procedure to determine the passing ability of self-consolidating concrete. This test method is applicable for laboratory use in comparing the passing ability of different concrete mixtures. It is also applicable in the field as a quality control test.

5.2 The difference between the slump flow and J-Ring flow is an indication of the passing ability of the concrete. A difference less than 25 mm [1 in.] indicates good passing ability and a difference greater than 50 mm [2 in.] indicates poor passing ability. The orientation of the mold for the J-Ring test and for the slump flow test without the J-Ring shall be the same.

5.3 This test method is limited to self-consolidating concrete with nominal maximum size of aggregate of up to 25 mm [1 in.].

Subcomité:

C09.47

Volúmen:

04.02

Número ICS:

91.100.30 (Concrete and concrete products)

Palabras clave:

halo; j-ring; j-ring flow; passing ability self-consolidating concrete; slump flow; spread;

$ 946

Agregar al carrito

Norma
C1621/C1621M

Versión
17(2023)

Estatus
Active

Clasificación
Test Method

Fecha aprobación
2023-10-01