Standard Test Method for Particulate Contamination in Aviation Fuels by Laboratory Filtration
Importancia y uso:
5.1 This test method provides a gravimetric measurement of the particulate matter present in a sample of aviation turbine fuel delivered to a laboratory for evaluation. The objective is to minimize these contaminants to avoid filter plugging and other operational problems. Although tolerable levels of particulate contaminants have not yet been established for all points in fuel distribution systems, the total contaminant measurement is normally of most interest.
Subcomité:
D02.J0.05
Referida por:
D2276-22, D1655-24, D6217-21, D8111-23A, D6824-23, D6469-24, D7843-21, D6217-21, D1655-24, D6615-22, D6824-23, D2276-22, D4865-23, D6469-24, D4865-23, D6468-22, D1655-24, D7843-21, D6217-21, D4306-20, D6468-22, D6986-03R20, D7566-24B, D0873-22, D4306-20, D6824-23, D6468-22, D8194-24, D6984-18E01, D7320-18E01
Volúmen:
05.02
Número ICS:
75.160.20 (Liquid fuels)
Palabras clave:
aviation fuel; gravimetric contaminant; membrane color; membrane filter; particulate;
$ 1,086
Norma
D5452
Versión
23
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2023-05-01