Standard Test Method for Monitoring of Atmospheric Corrosion Chambers by Quartz Crystal Microbalances


Importancia y uso:

4.1 Corrosion film growth with thicknesses varying from a monolayer of atoms up to 1 μm can readily be measured on a continuous, real-time, in-situ, basis with QCMs.

4.2 The test results obtained for this test method are influenced by various factors, including geometrical effects, temperature, humidity, film thickness, film materials, electrode conditions, gases in the corrosion chamber, atmospheric pressure, and so forth. Calibration of coated crystals and instrumentation and reproducible crystal operating conditions are necessary for consistent results.

Subcomité:

B02.05

Referida por:

B0827-05R20, B0845-97R24, B0825-19, B0826-09R20

Volúmen:

02.04

Número ICS:

77.060 (Corrosion of metals)

Palabras clave:

corrosion monitor; piezoelectric crystals, sensors, thin-film monitor;