Standard Test Method for Water and Sediment in Crude Oil by the Centrifuge Method (Laboratory Procedure)
Importancia y uso:
5.1 The water and sediment content of crude oil is significant because it can cause corrosion of equipment and problems in processing. A determination of water and sediment content is required to measure accurately net volumes of actual oil in sales, taxation, exchanges, and custody transfers. It is not anticipated that this test method, which is written with a dedicated laboratory facility in mind, is likely to be used in field test rooms or sample rooms due to safety concerns for proper ventilation and handling.
5.2 This test method may not be suitable for crude oils that contain alcohols that are soluble in water. In cases where the impact on the results may be significant, the user is advised to consider using another test method, such as Test Method D4928 (API MPMS Chapter 10.9).
Subcomité:
D02.02
Referida por:
F0631-15R20, D4177-22E01, F1084-08R24, D7666-12R19, F2084_F2084M-01R24, D4177-22E01, D4177-22E01, F2709-19, F3350-18R24, D4177-22E01
Volúmen:
05.01
Número ICS:
75.040 (Crude petroleum)
Palabras clave:
centrifuge; centrifuge tube; crude oil; laboratory procedure; sampling; sediment and water; solvent;
$ 1,202
Norma
D4007
Versión
22
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2022-10-01