Standard Practice for Use of a Calibration Device to Demonstrate the Inspection Capability of an Interferometric Laser Imaging Nondestructive Tire Inspection System


Importancia y uso:

5.1 All S/H systems change with time and use. Therefore, a calibration procedure for evaluating the operation of an S/H system is desirable. This calibration procedure provides a method of obtaining an optimized interferometric image pattern associated with a given size anomaly.

5.2 The use of straining blocks as calibration devices provides a means for ensuring the continued optimal performance of the S/H system. Straining blocks can also be used to compare performance of S/H systems in different facilities.

5.3 At not greater than a three (3) month interval the S/H system shall be calibrated following the procedures described in this practice. When necessary, adjustments, repairs, or modifications shall be made to the S/H system until it is able to observe, in the same image, all anomalies of size within the range of interest contained in the straining blocks.

Subcomité:

F09.10

Referida por:

E2581-14R23, E2533-21

Volúmen:

09.02

Número ICS:

31.260 (Optoelectronics. Laser equipment)

Palabras clave:

calibration; holography; inspection; nondestructive; shearography; tire;