Standard Test Method for Static Puncture Resistance of Roofing Membrane Specimens
Importancia y uso:
5.1 An important factor affecting the performance of many membrane roofing systems is their ability to resist static puncture loads. This test method provides a means for assessing static puncture resistance.
5.2 This test method can be used to compare the puncture resistance of a single type of membrane as a function of a variety of insulation substrates or, conversely, to compare the resistance of a number of membrane specimens set on a single type of insulation.
5.3 The effect of temperature on puncture resistance can be studied by conducting the test under controlled conditions using such equipment as an environmental chamber, oven, or freezer.
5.4 This test method can be useful for developing performance criteria for membrane roofing systems.
5.5 This test method can be useful for developing classifications of the static puncture resistance of membrane roofing systems.
5.6 While it is considered that the results obtained by this laboratory test can afford a measure of the static puncture resistance of membrane roofing systems in the field provided that service loads and temperature conditions are known, no direct correlation has yet been established.
5.7 This test method can be useful for evaluating the static puncture resistance of membranes used in vegetative roof systems.
Subcomité:
D08.20
Referida por:
D6630_D6630M-16R22, D3105-17R24, D4637_D4637M-15R21E01, D4434_D4434M-21, D6754_D6754M-23
Volúmen:
04.04
Número ICS:
91.100.50 (Binders. Sealing materials)
Palabras clave:
insulation substrate; membranes; puncture; roofing; static; test method;
$ 948
Norma
D5602/D5602M
Versión
18(2022)
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2022-11-01