Standard Test Method for Alternating-Current Magnetic Properties of Toroidal Core Specimens Using the Voltmeter-Ammeter-Wattmeter Method
Importancia y uso:
3.1 This test method is a derivative of Test Method A697/A697M specifically designed for testing of toroidal cores which are not covered in Test Method A697/A697M and for testing at magnetic flux densities above the knee of the magnetization curve.
3.2 Specimen size typically ranges from 1 in. to 1.25 in. [25.4 mm to 31.8 mm] in inside diameter to 1.5 in. [38.1 mm] in outside diameter with weights ranging from 30 g to 60 g. Provided the test equipment is suitably chosen, there is no obvious limit to the overall size of core that can be tested. If basic material properties are desired, then the requirements of 5.1 must be observed.
3.3 The reproducibility and repeatability of this test method are such that this test method is suitable for design, specification acceptance, service evaluation, and research and development.
3.4 When testing under sinusoidal flux conditions at magnetic flux densities approaching saturation, highly peaked magnetizing waveforms will be present, and the test instruments used must have crest factor capabilities of at least 3; otherwise erroneous results will be obtained.
Subcomité:
A06.01
Referida por:
B0925-15R22, A1086-20
Volúmen:
03.07
Número ICS:
17.220.20 (Measurement of electrical and magnetic quantities)
Palabras clave:
alternating current; core; core loss; flat rolled; laminated core; lamination; magnetic; magnetic material; magnetic test; permeability;
$ 1,085
Norma
A927/A927M
Versión
18(2022)
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2022-10-01