Standard Practice for Standardizing Equipment and Electromagnetic Examination of Seamless Aluminum-Alloy Tube
Importancia y uso:
4.1 The examination is performed by passing the tube lengthwise through or near an eddy current sensor energized with alternating current of one or more frequencies. The electrical impedance of the eddy current sensor is modified by the proximity of the tube. The extent of this modification is determined by the distance between the eddy current sensor and the tube, the dimensions, and electrical conductivity of the tube. The presence of metallurgical or mechanical discontinuities in the tube will alter the apparent impedance of the eddy current sensor. During passage of the tube, the changes in eddy current sensor characteristics caused by localized differences in the tube produce electrical signals which are amplified and modified to actuate either an audio or visual signaling device or a mechanical marker to indicate the position of discontinuities in the tube length. Signals can be produced by discontinuities located either on the external or internal surface of the tube or by discontinuities totally contained within the tube wall.
4.2 The depth of penetration of eddy currents in the tube wall is influenced by the conductivity (alloy) of the material being examined and the excitation frequency employed. As defined by the standard depth of penetration equation, the eddy current penetration depth is inversely related to conductivity and excitation frequency (Note 2). Beyond one standard depth of penetration (SDP), the capacity to detect discontinuities by eddy currents is reduced. Electromagnetic examination of seamless aluminum alloy tube is most effective when the wall thickness does not exceed the SDP or in heavier tube walls when discontinuities of interest are within one SDP. The limit for detecting metallurgical or mechanical discontinuities by way of conventional eddy current sensors is generally accepted to be approximately three times the SDP point and is referred to as the effective depth of penetration (EDP).
Note 2: The standard depth of penetration is defined by the following equations:
where:
SDP = one standard depth of penetration, m, f = frequency, Hz (cycles per second), and σ = conductivity, Siemens/metre.
or:
where:
SDP = one standard depth of penetration, in., f = frequency in Hz (cycles per second), and σ = conductivity, % IACS.
Subcomité:
E07.07
Referida por:
B0491_B0491M-23, B0210_B0210M-19A, B0234-17, E0426-16R21, B0234M-17, E0543-21, B0483_B0483M-21, E3166-20E01, E0543-21, E2982-21
Volúmen:
03.03
Número ICS:
77.040.20 (Non-destructive testing of metals)
Palabras clave:
aluminum alloy; eddy currents; electromagnetic examination; equipment standardization; NDT; nondestructive testing; tubing ;
$ 1,191
Norma
E215
Versión
22
Estatus
Active
Clasificación
Practice
Fecha aprobación
2022-06-01