Standard Practice for Moisture Surveying of Roofing and Waterproofing Systems Using Nondestructive Electrical Impedance Scanners
Importancia y uso:
5.1 Excess moisture trapped in roofing or waterproofing systems can adversely affect performance and lead to premature failure of roofing or waterproofing systems and its components. It also reduces thermal resistance, resulting in reduced energy efficiency and inflated energy costs. Impedance scans can be effective in identifying concealed and entrapped moisture within roofing or waterproofing systems.
5.2 This practice is intended to be used at various stages of the roofing and waterproofing system’s life such as: during or at completion of installation of roofing or waterproofing system to determine if there was moisture intrusion into the roofing or waterproofing system or underlying materials; at regular intervals as part of a preventative maintenance program; and to aid in condition assessment, or before replacement or repair work, or combinations thereof, to assist in determining the extent of work and replacement materials.
5.3 This practice alone does not determine the cause of moisture infiltration into roofing or waterproofing systems; however, it can be used to help tracing excess moisture to the point of ingress.
Subcomité:
D08.20
Volúmen:
04.04
Número ICS:
91.060.20 (Roofs), 91.100.60 (Thermal and sound insulating materials)
Palabras clave:
core sample; detection; impedance; moisture content; moisture detection; moisture scanner; nonconductive; nondestructive; roofing system; scanner; waterproofing;
$ 1,092
Norma
D7954/D7954M
Versión
22a
Estatus
Active
Clasificación
Practice
Fecha aprobación
2022-05-01