Standard Practice for Separation of Ignitable Liquid Residues from Fire Debris Samples by Passive Headspace Concentration with Activated Charcoal
Importancia y uso:
4.1 This practice is useful for preparing extracts from fire debris for later analysis by gas chromatography mass spectrometry.
4.2 This is a very sensitive separation procedure, capable of isolating quantities smaller than 1/10 μL of ignitable liquid residue from a sample.
Subcomité:
E30.13
Referida por:
E3197-23, E1732-24E01, E1618-19, E1386-23, E1388-24, E3189-19, E1413-19, E2451-21, E2997-16, E3245-20E01, E2881-18
Volúmen:
14.02
Número ICS:
13.220.99 (Other standards related to fire protection)
Palabras clave:
activated charcoal; fire debris samples; forensic science; passive headspace concentration;
$ 1,053
Norma
E1412
Versión
19
Estatus
Active
Clasificación
Practice
Fecha aprobación
2019-11-15