Standard Test Method for Oxygen Content Using a 14-MeV Neutron Activation and Direct-Counting Technique


Importancia y uso:

5.1 The conventional determination of oxygen content in liquid or solid samples is a relatively difficult chemical procedure. It is slow and usually of limited sensitivity. The 14-MeV neutron activation and direct counting technique provides a rapid, highly sensitive, nondestructive procedure for oxygen determination in a wide range of matrices. This test method is independent of the chemical form of the oxygen.

5.2 This test method can be used for quality and process control in the metals, coal, and petroleum industries, and for research purposes in a broad spectrum of applications.

Subcomité:

E10.05

Volúmen:

12.02

Número ICS:

27.120.30 (Fissile materials and nuclear fuel technology)

$ 1,119

Agregar al carrito

Norma
E385

Versión
22

Estatus
Active

Clasificación
Test Method

Fecha aprobación
2022-02-01