Standard Specification for General Requirements for Wrought Precious Metal Electrical Contact Materials
Importancia y uso:
11.1 For purpose of determining compliance with the specified limits for requirements of the properties listed in the following table, an observed value or a calculated value shall be rounded as indicated in accordance with Practice E29.
Property
Unit
Rounded Unit
for Observed or
Calculated Value
Chemical composition
percent
Hardness
Knoop (100-g load unless other-
wise specified)
Vicker (specify load)
Rockwell (all scales, specify which)
Rockwell superficial (all scales,
specify which)
nearest unit on the last right
hand place of figure of
specified limit
Resistivity
μΩ·cm
Tensile strength
psi (MPa)
nearest 1000 psi (nearest 10
MPa)
Yield Strength
psi (MPa)
nearest 1000 psi (nearest
10 MPa)
Elongation
Below 5 %
percent
nearest multiple of 0.5 %
5 % and over
percent
nearest 1 %
Grain size
Up to 0.055 mm incl.
mm
nearest multiple of 0.005
mm
Over 0.055 to 0.160, mm, incl.
mm
nearest 0.01 mm
Subcomité:
B02.05
Referida por:
B0522-01R21, B0685-20, B0683-20, B0628-98R21, B0780-16R21, B0617-98R21, B0693-17R22, B0477-21, B0684_B0684M-22, B0844-98R21, B0541-24, B0596-21, B0563-01R22, B0540-21
Volúmen:
02.04
Número ICS:
77.120.99 (Other non-ferrous metals and their alloys)
Palabras clave: