Standard Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method


Importancia y uso:

5.1 The techniques described provide indirect measurement of thickness of sections of materials not exceeding temperatures of 93 °C [200 °F]. Measurements are made from one side of the object, without requiring access to the rear surface.

5.2 Ultrasonic thickness measurements are used extensively on basic shapes and products of many materials, on precision machined parts, and to determine wall thinning in process equipment caused by corrosion and erosion.

5.3 Recommendations for determining the capabilities and limitations of ultrasonic thickness gages for specific applications can be found in the cited references.7,8

Subcomité:

E07.06

Referida por:

G0158-23, F1216-24, E3166-20E01, E3370-24

Volúmen:

03.03

Número ICS:

17.040.20 (Properties of surfaces)

Palabras clave:

contact examination; nondestructive testing; pulse-echo; thickness measurement; ultrasonics;

$ 1,119

Agregar al carrito

Norma
E797/E797M

Versión
21

Estatus
Active

Clasificación
Practice

Fecha aprobación
2021-06-01