Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
Importancia y uso:
5.1 Flash point measures the response of the test specimen to heat and ignition source under controlled laboratory conditions. It is only one of a number of properties that must be considered in assessing the overall flammability hazard of a material.
5.2 Flash point is used in shipping and safety regulations by governmental regulatory agencies to define flammable and combustible materials and to classify them. Consult the particular regulation involved for precise definitions of these classes.
5.3 Flash point can indicate the possible presence of highly volatile and flammable impurities or contaminants in a given liquid, such as the presence of residual solvents in solvent-refined drying oils.
5.4 These equilibrium flash point test methods use a smaller specimen (2 mL) and a shorter test time (1 min) than traditional non-equilibrium test methods such as Test Method D56 and Test Methods D93.
5.5 Test Methods D3828, Test Method D8174, and ISO 3679 are similar test methods and use the same apparatus.
Subcomité:
D01.21
Referida por:
D0268-22, D3757-16, D0333-01R21, D3105-17R24, E0502-21A, D4800-94R23, D4733-17, D6361_D6361M-98R20, D0235-22, D0115-17R24, E1232-07R19, D3794-22, C0461-23, F0718-22, D0056-22, D6577-24, D3735-22, D0803-24, D6465-99R24, D3734-05R18, F0940-99R19E01, D0056-22, D3934-20, D3730-17R22, D6763-16R22, D3955-20, D5146-10R19, D0056-22
Volúmen:
06.01
Número ICS:
13.220.40 (Ignitability and burning behaviour of materials and products), 87.040 (Paints and varnishes)
Palabras clave:
flash/no flash; flash point; organic peroxides; organic solvents; small scale closed-cup apparatus;
$ 1,194
Norma
D3278
Versión
21
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2021-06-15