Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material


Importancia y uso:

4.1 Laboratories performing petroleum test methods can use this practice to set an acceptable tolerance zone for infrequent testing of CS or CCS material, based on ε, and a desired Type I error, for the purpose of ascertaining if the test method is being performed without bias.

4.2 This practice can be used to estimate the power of correctly detecting bias of different magnitudes, given the acceptable tolerance zone set in 4.1, and hence, gain insight into the limitation of the true bias detection capability associated with this acceptable tolerance zone. With this insight, trade-offs can be made between desired Type I error versus desired bias detection capability to suit specific business needs.

4.3 The CS testing activities described in this practice are intended to augment and not replace the regular statistical monitoring of test method performance as described in Practice D6299.

Subcomité:

D02.94

Referida por:

D6792-23C, D7372-21, D0445-24, D7372-21, D7911-19, D6792-23C, D7042-21A, D7042-21A, D7042-21A, D0445-24, D6299-23A, D7372-21, D7042-21A, D6299-23A, D0445-24, D6792-23C, D6299-23A

Volúmen:

05.03

Número ICS:

19.020 (Test conditions and procedures in general)

Palabras clave:

accepted reference value; bias; check standard; consensus; power of test; probability of bias detection; type I error; type II error;