Importancia y uso:
3.1 Water-blast cleaning with (SSPC-TR2/NACE 6G 198; SSPC-SP 5 (WAB)/NACE WAB-1; SSPC-SP 10 (WAB)/NACE WAB-2; SSPC-SP 6 (WAB)/NACE WAB-3; SSPC-SP 14 (WAB)/NACE WAB-8); SSPC-SP 7 (WAB)/NACE WAB-4 or without, (SSPC-SP WJ-1/NACE WJ-1; SSPC-SP WJ-2/NACE WJ-2; SSPC-SP WJ-3/NACE WJ-3; SSPC-SP WJ-4/NACE WJ-4) abrasive, results in flash rusting under some environmental conditions. Inhibitors are used to prevent flash rusting while drying and before coating application. The inhibitor or reaction products of the inhibitor on the substrate becomes part of the coating systems. Coating performance may be influenced by the inhibitor. Soluble contaminants or unreacted inhibitors left on the surface under the coating may cause premature failure. This practice includes a comparison of coating performance with and without inhibitors using various laboratory tests to simulate a range of conditions such as high moisture, marine atmospheric or water immersion.
3.2 The user or specifier must determine the specific test methods to be used and exposure conditions. Some test methods referenced may not be applicable to all types of coatings.
Subcomité:
D01.46
Referida por:
D4538-21
Volúmen:
06.02
Número ICS:
87.040 (Paints and varnishes)
Palabras clave:
abrasive blasting; coatings; inhibitors; surface preparation; water blasting;