Standard Guide for Management of Non-Conforming Coatings in Coating Service Level I Areas of Nuclear Power Plants


Importancia y uso:

5.1 There are several methods for managing non-conforming coatings in an operating nuclear power plant. This guide outlines methods that have been determined to be acceptable to the nuclear industry.

5.2 Managing the amount of non-conforming coatings is key to ensuring the amount assumed, in the licensing bases is not exceeded.

5.3 EPRI Report 1019157 provides additional information on the selection, application, inspection and maintenance of nuclear plant safety-related protective coatings. This reference offers a detailed discussion of important considerations related to protective coatings and can be used to supplement this guide as deemed necessary.

Subcomité:

D33.10

Referida por:

D4538-21, D5144-08R21

Volúmen:

06.02

Número ICS:

27.120.20 (Nuclear power plants. Safety)

Palabras clave:

Design Basis Accident (DBA); Emergency Core Cooling System (ECCS) suction strainer; licensing basis; safety related;