Standard Test Method for Cloud Point of Petroleum Products and Liquid Fuels (Optical Detection Stepped Cooling Method)
Importancia y uso:
5.1 For petroleum products and biodiesel fuels, the cloud point is an index of the lowest temperature of their utility for certain applications. Wax crystals of sufficient quantity can plug filters used in some fuel systems.
5.2 Petroleum blending operations require precise measurement of the cloud point.
5.3 This test method can determine the temperature of the test specimen at which wax crystals have formed sufficiently to be observed as a cloud with a resolution of 0.1 °C.
5.4 This test method provides results that, when rounded to the next lower integer, are equivalent to Test Method D2500. Refer to 12.2.
5.5 This test method is more precise than Test Method D2500.
Note 1: According to interlaboratory examination, the reproducibility of this test method has been found to be more precise than Test Method D2500.
Subcomité:
D02.07
Referida por:
D6751-24, D0975-24A, D6371-24, D6371-24, D6751-24, D6371-24, D0975-24A, D7467-23, D7467-23, D0975-24A, D6751-24
Volúmen:
05.02
Número ICS:
75.160.20 (Liquid fuels)
Palabras clave:
automatic cloud point; cloud point; petroleum products;