Standard Practice for Measuring the Change in Length of Bolts Using the Ultrasonic Pulse-Echo Technique


Importancia y uso:

5.1 The techniques described provide for the measurement of change in length of a fastener. Such measurements are made from one end of the specimen without requiring access to the rear surface.

5.2 The Ultrasonic Pulse Echo technique is used to monitor changes in length of fasteners and as a tool for industrial quality control. Applications include fasteners used in turbines, petrochemical pressure vessels, aircraft, automotive manufacturing, general bolting within the nuclear industry, structural steel connections, and laboratory testing.

Subcomité:

E28.13

Referida por:

E1982-98R21, F2482_F2482M-21

Volúmen:

03.01

Número ICS:

17.040.30 (Measuring instruments), 21.060.01 (Fasteners in general)

Palabras clave:

bolts; change-in-length measurements; stress measurements; ultrasonics. ;

$ 1,087

Agregar al carrito

Norma
E1685

Versión
20

Estatus
Active

Clasificación
Practice

Fecha aprobación
2020-10-01