Standard Test Method for Acetone Extraction of Phenolic Molded or Laminated Products
Importancia y uso:
4.1 For molded phenolic products, acetone extraction shall be considered solely as a quantitative expression of a property normally associated with degree of cure. There is no demonstrably rigorous relation between the optimum mechanical and electrical properties of a well-cured piece and the numerical value of the acetone test. The amount of acetone-soluble matter is affected by: (1) nature of resin and filler, (2) lubricant, (3) molding temperature, (4) length of cure, (5) thickness of the section from which sample is taken, (6) nature of molded piece, (7) technique used in molding, (8) distribution of fines in the material to be extracted, and (9) method of grinding the specimen. These variations under some conditions will cause a difference of 3 to 4 % in acetone-extractable matter. For this reason, the test method shall be used only as a comparative test for measuring undercure.
4.2 For laminated phenolic products, acetone extraction indicates change in stage of cure, change in resin content, change in type of resin used, presence of plasticizers or other acetone-extractable addition agents, and is affected in general by the same factors as stated in 6.1
Subcomité:
D20.70
Referida por:
D0229-19E01, D2654-22
Volúmen:
08.01
Número ICS:
83.140.20 (Laminated sheets)
Palabras clave:
acetone extraction; cure; laminated plastic; molded plastic; phenolic resin; plasticizers;
$ 952
Norma
D494
Versión
11(2019)
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2019-11-01