Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass
Importancia y uso:
5.1 This practice provides a design load suitable for sizing blast resistant glazing comprised of laminated glass or insulating glass fabricated with laminated glass.
5.2 Blast resistant glazing comprised of laminated glass or insulating glass fabricated with laminated glass shall be sized to resist the 3-second duration equivalent design loading from this standard practice using the procedures described in Practice E1300.
5.3 In the event a blast loading does not occur to blast resistant glazing comprised of laminated glass or insulating glass fabricated with laminated glass sized using the 3-second duration loading determined herein, the blast resistant glazing will have a probability of breakage less than or equal to 8 lites per 1000 at the first occurrence of a loading equal to the 3-second duration design loading determined herein.
5.4 Blast resistant glazing designed to resist the 3-second equivalent load as determined herein, when properly supported as part of a blast resistant glazing system, is designed to perform to minimal hazard as defined in Test Method F2912.
Subcomité:
F12.10
Referida por:
F2912-17
Volúmen:
15.08
Número ICS:
81.040.30 (Glass products)
Palabras clave:
air blast pressure; blast resistant glazing; explosion; insulating glass; laminated glass; specified design load;
$ 1,121
Norma
F2248
Versión
19
Estatus
Active
Clasificación
Practice
Fecha aprobación
2019-05-01