Standard Practice for Data Recording Procedure for Welding Devices Used to Produce Thermal Fusion Welds in Geomembrane Systems
Importancia y uso:
4.1 Standard wedge welding devices rely on the operator to properly adjust the welding parameters (temperature, speed, and pressure) which are needed to create a sound weld. Changes in one or more of these parameters during production seaming, whether deliberate or accidental, can lead to poor weld quality. Prior to data acquisition systems, verifying welding parameters throughout the welding process relied solely on periodic visual observations and documentation, leaving substantial room for error. This ASTM standard practice, which requires a data acquisition system to be installed on thermal fusion welding devices, allows for the recording of these welding parameters along the entire length of the welded seam at pre-determined intervals, throughout the entire thermal fusion seaming process.
4.2 The acquired data can be used in the construction quality control / construction quality assurance program to compare the welding parameters at recorded locations along the welded length to preset values, such as the values obtained during the trial seam, to facilitate detection of anomalies anywhere on the welded length.
4.3 This practice does not cover the precision of the measurement, that is, the accuracy of the recorded values of temperature, speed, pressure, or position on the site. It is limited to the data acquisition process.
4.4 Data acquisition parameters, such as the frequency at which the data are recorded, may be adjusted by the user depending on project specifications.
Subcomité:
D35.10
Referida por:
D8580-24
Volúmen:
04.13
Número ICS:
25.160.30 (Welding equipment), 59.080.70 (Geotextiles)
$ 954
Norma
D8468
Versión
23
Estatus
Active
Clasificación
Practice
Fecha aprobación
2023-01-01