Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure and Temperature Differences Across the Specimen
Importancia y uso:
5.1 The exterior building envelope and its components (for example, windows and doors) separate the interior conditioned spaces from exterior environmental factors such as heat, cold, rain, wind, noise dust, etc. Building materials and components can expand or contract to varying degrees, depending on seasonal and diurnal exterior ambient air temperatures. Fluctuations in the ambient air temperatures can alter the sealing characteristics of windows, curtain walls, and doors by changing weather seal compression ratios. Thermal expansion or contraction of framing materials coupled with thermal blowing due to temperature gradients through the product, and alterations in the effective leakage areas due to weather seal shrinkage and compression set, can also significantly alter the air leakage rates of these products in field service applications. Air leakage tests performed using Test Method E283 (a laboratory air leakage test performed at ambient temperature conditions) will not account accurately for changes in air leakage rates that may occur from dimensional changes in fenestration systems, materials, and components.
5.2 It is recommended that test specifiers consult the manufacturer for recommended test temperature extremes.
5.3 This procedure provides a means for evaluating air leakage rates of fenestration systems under various temperature and pressure conditions and air flow directions. It is also applicable for use in evaluating the efficiency of weather sealing products in fenestration systems. All air flow rates are converted to standard conditions to provide a means of comparison between measurements made at different ambient air temperature and pressure conditions.
5.4 Air leakage rates are sometimes used for comparison purposes. Such comparisons may not be valid unless the components being tested and compared are of essentially the same size, configuration, and design.
Subcomité:
E06.51
Referida por:
E2708-24, E1677-23, E1423-21, E3021_E3021M-15R19, E0283_E0283M-19, E2357-24, C1401-23, C1363-24
Volúmen:
04.11
Número ICS:
91.060.50 (Doors and windows)
Palabras clave:
air leakage; curtain walls; differential temperature; doors; energy analysis; fenestration; laboratory method; static pressure chamber; testing; test method; windows ;
$ 1,087
Norma
E1424
Versión
22
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2022-10-01