Standard Test Method for Wind Resistance of Concrete and Clay Roof Tiles (Air Permeability Method)
Importancia y uso:
5.1 The air permeability of roofing systems constructed from discrete elements, as is the case for clay and concrete tile and slate roof systems, is a critical factor in determining the wind resistance of the roof system. The ability of the roof system to relieve wind-induced uplift pressures as a result of the overall air permeability of the roof assembly relates to the resistance of the roof system to damage induced by wind.
5.2 Natural wind conditions differ with respect to intensity, duration, and turbulence; these conditions are beyond the means of this test method to simulate.
Subcomité:
C15.06
Referida por:
C1569-22, C1232-24
Volúmen:
04.05
Número ICS:
91.060.20 (Roofs)
Palabras clave:
air permeability method; clay roof tile; concrete roof tile; critical upward pressure difference; uplift resistance; wind resistance;
$ 946
Norma
C1570
Versión
22
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2022-03-01