Standard Practice for Demonstrating Equivalent In-Plane Lateral Seismic Performance to Wood-Frame Shear Walls Sheathed with Wood Structural Panels
Importancia y uso:
5.1 This practice documents cyclic performance benchmarks for shear walls constructed with wood structural panel (WSP) sheathing attached to dimension lumber framing using common or galvanized box nails as defined in 3.2.8.
5.2 Procedures described in this practice provide a method to evaluate an alternative shear wall system’s SEPs to demonstrate equivalent in-plane lateral seismic performance to the reference shear wall system.
5.3 The procedures described in this practice do not address all factors to be considered for recognition of an alternative shear wall system. Such factors, as described in 1.4, vary by the end-use application and shall be addressed outside the scope of this standard through an evaluation of the acceptability of the alternative shear wall system in accordance with requirements of building codes and standards, as applicable.
Subcomité:
D07.05
Volúmen:
04.10
Número ICS:
79.060.01 (Wood-based panels in general), 91.060.10 (Walls. Partitions. Facades)
Palabras clave:
cyclic loads; earthquake, shear wall; lateral force; seismic; wood structural panel; ;
$ 1,092
Norma
D7989
Versión
21
Estatus
Active
Clasificación
Practice
Fecha aprobación
2021-11-01