Standard Test Method for Slump Flow of Self-Consolidating Concrete


Importancia y uso:

5.1 This test method provides a procedure to determine the slump flow of self-consolidating concrete in the laboratory or the field.

5.2 This test method is used to monitor the consistency of fresh, unhardened self-consolidating concrete and its unconfined flow potential.

5.3 It is difficult to produce self-consolidating concrete that is both flowable and nonsegregating using coarse aggregates larger than 25 mm [1 in.]. Therefore, this test method is considered applicable to self-consolidating concrete having coarse aggregate up to 25 mm [1 in.] in size. Appendix X1 provides non-mandatory visual rating criteria that may be used to classify the ability of a self-consolidating concrete mixture to resist segregation (stability).

5.4 The rate at which the concrete spreads is related to its viscosity. Appendix X1 provides a non-mandatory procedure that may be used to provide an indication of relative viscosity of self-consolidating concrete mixtures.

Subcomité:

C09.47

Referida por:

C1621_C1621M-17R23, C0125-21A, C1903-24, C0031_C0031M-24B, C1758_C1758M-23, C1019-24, C1712-20, C1019-24, C1758_C1758M-23, C1890-19, C1712-20, C0094_C0094M-24C, C0476-23, C1776_C1776M-17R22, C0031_C0031M-24B, C0192_C0192M-19, C0031_C0031M-24B, C1621_C1621M-17R23, C0192_C0192M-19, C0192_C0192M-19

Volúmen:

04.02

Número ICS:

91.100.30 (Concrete and concrete products)

Palabras clave:

halo; self-consolidating concrete; slump flow; spread; stability; viscosity; visual stability index;

$ 1,084

Agregar al carrito

Norma
C1611/C1611M

Versión
21

Estatus
Active

Clasificación
Test Method

Fecha aprobación
2021-05-15