Standard Test Method for Measuring the Flow Rate of Aerosol Foam Sealants
Importancia y uso:
5.1 This test method provides a calculated data point regarding the amount of foam dispensed at one time from a single can of foam at standard laboratory conditions or a specific temperature and relative humidity range.
5.2 Flow Rate does not predict the performance capability of the foam sealant or its suitability for the intended application.
5.3 Flow Rate can be measured with a testing machine (Procedure B) or with the intended applicator or dispensing unit (Procedure A).
5.4 The test is suitable for product performance certification and quality control programs, and can be useful to the general public, aerosol foam sealant manufacturers, distributors, specifiers, architects, contractors, testing laboratories, and other businesses and professionals.
Subcomité:
C24.61
Referida por:
C1737-24
Volúmen:
04.07
Número ICS:
91.100.50 (Binders. Sealing materials)
Palabras clave:
aerosol; aerosol foam; air infiltration; foam sealant; latex foam sealant; polyurethane foam sealant;
$ 952
Norma
C1806
Versión
21
Estatus
Active
Clasificación
Test Method
Fecha aprobación
2021-05-15